Our Location
304 North Cardinal St.
Dorchester Center, MA 02124
Original price was: $2,348.25.$298.98Current price is: $298.98.
Energy-efficient Peltier design
Digital control to 1°C from -20°C to 100°C without sample block
Control at ambient
Built-in data logger
Count down timer (up to 30 days) with audible alarm and user settable Auto-Off
RS232 I/O port for data collection
Electronic calibration. Factory set, but user can set to any local standard
Small, compact size. Uses very little bench space
12-volt DC operation. External power supply provided
12-month warranty
UL, CSA and CE compliant
Unattended restriction digestions or ligations at elevated temperatures then reducing temperature to 4°C automatically to reduce non-specific nuclease digestion of target DNA
Automatically stopping reactions by having the unit reduce sample temperature after a specific reaction time
Producing denatured probes or single stranded DNA molecules by heating to 90°C/95°C for a given time and rapidly reducing temperature to 4°C to prevent renaturation
Automatic temperature profiles to grow bacteria at 37°C, then increasing temperature to induce events, and then lowering temperature to 4°C to prevent degradation
Maintaining 14°C for ligation reactions
Enzyme reactions and deactivations
Maintaining 17°C for storing oocytes
Storing reagents at 4C in 15, 50, 250, and 500ml centrifuge tubes
Storing samples at ice bucket temperatures without the mess
Incubating samples at 37°C in 96-well assay plates or in aluminum blocks holding 0.2, 0.5 and 1.5 ml centrifuge tubes, vials, and test tubes
Storing enzyme or DNA libraries at your workstation
Freezing and storing most any sample at your workstation
Temperature
Range: -20°C to 100°C
Readability: 1°C
Accuracy: ±1°C
Stability: ±1°C
Sensor Type: Platinum RTD
Controller Type: PID
Uniformity: ±0.5°C
Timer
Range: 00:01 to 30 days
Readability: 1 second
Audible Alarm: Yes, alarm sounds for 1 minute. Timer counts up until UP or DOWN key is touched
Programming
Programs Stored: 5
Individual Program Capacity: 10 Steps
Program Repeat: 1–99 times
Memory Backup: Yes, in CMOS
Data Logger
Sample times: 1 sec, 1 min or 5 minutes per data point
Capability: 7825 data points
Electrical
Heater/Chiller: Peltier Module 100 watts
Operating Voltages: From 90 to 265 volts AC into universal power supply. 12 VDC output to chiller/heater module
Power Consumption: 100 watts
Power Switch: Yes
Chilling/Heating Module Dimensions
Width: 8.5″ (21.6 cm)
Depth:10″ (25.4 cm)
Height: 4.0″ (10.2 cm)
Power Supply Dimensions
Length: 6.5” (16.5 cm)
Height: 3.2” (8.1 cm)
Width: 2.2” (5.6 cm)
Weight (power supply & chiller/heater module): 8 lbs (3.6 kg)
Product Overview
| SKU | I174049 |
|---|---|
| Part No. | IC30XT |
| Brand | Torrey Pines Scientific |
| Adjustment | Digital |
| Range | 20° to 100°C |
| Input | 100 to 265V |
Reviews
There are no reviews yet.